Residual Oxygen Levels in Inert Gas Packaging AtmoCheck OPTIC O2

100112

New product

Brand: HiTec Systems

The AtmoCheck® analyser works without a pump, and can therefore be used to accurately measure O2 in extremely small headspace volumes. Examples of where this machine excells are: modified atmosphere packaging (MAP) with a minute headspace, or very small blister packs for pharmaceuticals. Measuring range <0.0 to 100%, resolution 0,01% absolute with accuracy of ±0,05% absolute.

More details

8 719,20€ tax excl.

Add to wishlist

More info

Key Features:

  • Application range for headspace volume <2 ml
  • Measuring range < 0.05% - 100%
  • Short measuring time <2 sec.
  • Intuitive operation via 10" colour touchscreen display
  • Integrated data logging software
  • Graphic display
  • Auto-Calibration Function
  • Product menu and product management
  • Ethernet connection for integration into networks
  • Easy hygienic care due to splash-proof design
  • Simple calibration in air via integrated SPAN procedure
  • Low maintenance and robust design
  • Also suitable for long-term testing
  • Simple, intuitive handling
  • Low volume of sample gas required for measurement
  • USB, Ethernet interface
  • Large, clear illuminated graphic display
  • Easy to use re-calibration feature
  • Modern and functional Stainless steel housing
  • Outstanding price/performance ratio
  • Backlighting
  • 1 year guarantee
  • Power off automatically
  • Made in United Kingdom

AtmoCheck® analysers are in a class of their own and are characterised by decades of experience, exceptional measurement performance, robust design and simple intuitive operation.

In order to ensure and achieve the highest possible product quality, just rapidly test the residual oxygen content to the highest accuracy with AtmoCheck® OPTIC O2.

Food Industry Applications

The use of gases in the food industry in order to increase product quality and extend the shelf life of food is well established and helps to achieve:

  • Quality Assurance
  • Attractive Appearance
  • Extended Shelf Life
  • Fewer Preservatives

With our AtmoCheck® OPTIC O2 analyser you can easily ensure the consistent high quality of your products by regularly checking the inert gas atmosphere. Ideal for quality control of MAP packaging with an extremely small headspace volume.

  • MAP Packaging
  • Vacuum Packaging
  • Liquid Products
  • Coffee Packaging
  • Coffee Capsules, Coffee Pods
  • Milk Powder, Milk Powder Sachets

AtmoCheck® OPTIC O2 is also optionally available for use directly on the packaging machine.

Pharmaceutical Industry Applications

Gases used in the production of active substances and pharmaceuticals are also used in in a wide variety of areas and for various requirements, for example:

  • as high purity gases for the laboratory
  • as specialty gases for research and development
  • as process gases for manufacturing processes such as chemical synthesis
  • as inert gases for the removal of atmospheric oxygen
  • as gases for sterile processes
  • as traceable gases for GMP requirements
  • as gas mixtures for measurements in the laboratory or in environmentals
  • as gases for the cultivation of organic crops

Many pharmaceutical products are very sensitive to atmospheric oxygen and moisture. Packaging in a protective atmosphere effectively prevents drugs from losing their effectiveness. The shelf life of therapeutic proteins in particular, which may be produced using nitrogen, is significantly extended.

AtmoCheck® OPTIC O2 can optionally be used for the measurement of dissolved oxygen in a liquid.

All highlights at a glance

  • Application range for headspace volume < 2 ml
  • Measuring range < 0.05% - 100%
  • Short measuring time < 2 sec.
  • Intuitive operation via 10" colour touchscreen display
  • Integrated data logging software
  • Graphic display
  • Auto-Calibration Function
  • Product menu and product management
  • Ethernet connection for integration into networks
  • Easy hygienic care due to splash-proof design
  • Simple calibration in air via integrated SPAN procedure
  • Low maintenance and robust design
  • Also suitable for long-term testing

Special Features

AtmoCheck® OPTIC O2 can be used in extreme conditions where traditional gas analysers cannot operate. The challenge of creating a sensor capable of measuring a miniscule headspace was to protect the sensor from food particles, powder or liquid. This was achieved with our new Optical Sensor Technology.

The outstanding feature of AtmoCheck® OPTIC O2, is that the Sensor is the only item that ever requires cleaning, and this is simplicity itself, taking literally only a few seconds.

In order to remove all soiling caused by either dry or liquid product residues that may remain on the sensor, all you need is just a glass of water. Simply place the tip of the sensor into the water and stir it for a couple of seconds. The sensor is then ready for use again within the shortest possible time.

The AtmoCheck® OPTIC O2 is therefore virtually impervious to both solid and/or liquid contaminants.

AtmoCheck® OPTIC O2 is intuitive, easy and safe to use. With a simple tap on the user interface you can control all functions; select products, create new products or users, etc.

Display of measured values, selected product, measuring time and limit values are clearly displayed on the large 10" touch display.

Note: When operating the Atmocheck equipment, for its readings to be taken correctly, it is essential to use accessories from the manufacturer HTK. The use of accessories from another brand compromises the records and proper functioning of the equipment and may lead to the automatic termination of the warranty.

Reviews

Write a review

Residual Oxygen Levels in Inert Gas Packaging AtmoCheck OPTIC O2

Residual Oxygen Levels in Inert Gas Packaging AtmoCheck OPTIC O2

Brand: HiTec Systems

The AtmoCheck® analyser works without a pump, and can therefore be used to accurately measure O2 in extremely small headspace volumes. Examples of where this machine excells are: modified atmosphere packaging (MAP) with a minute headspace, or very small blister packs for pharmaceuticals. Measuring range <0.0 to 100%, resolution 0,01% absolute with accuracy of ±0,05% absolute.

22 other products in the same category: