Waterproof Dissolved Oxygen Meter for Water Analysis - Senseca ECO 531

ECO 531

New product

Dissolved oxygen measurement is an important parameter in water quality assessment, aquatic ecosystem monitoring, aquaculture and fish farming.

More details

349,60€ tax excl.

Add to wishlist

More info

SENSECA • ECO 531 • DISSOLVED OXYGEN • O₂ • AQUACULTURE • WATER ANALYSIS

Senseca ECO 531

Waterproof Dissolved Oxygen Meter for Water Analysis
Professional handheld water analysis meter featuring a galvanic oxygen sensor with active membrane, dissolved oxygen concentration measurement up to 20 mg/l, oxygen saturation up to 200 %, integrated temperature measurement and automatic calibration in ambient air.
Dissolved oxygen: 0.0...20.0 mg/l or ppm O₂
Oxygen saturation: 0...200 %
Sensor: galvanic active membrane with integrated temperature measurement
Salinity correction: 0...70 PSU
Calibration: automatic calibration in ambient air
Housing protection: IP65 / IP67
Battery life: more than 3000 h without backlight

Request a Quote

View Technical Specifications

The Senseca ECO 531 is a portable instrument designed to measure dissolved oxygen concentration in mg/l or ppm O₂, oxygen saturation in percent and water temperature.

Its permanently connected galvanic oxygen probe with active membrane incorporates integrated temperature measurement, while configurable salinity and environmental pressure settings support measurements under different water conditions.

The robust ABS housing, IP65/IP67 protection, backlit LCD and battery life exceeding 3000 hours make the ECO 531 a practical solution for regular field measurements.

Dissolved Oxygen, Saturation and Temperature in One Instrument

The Senseca ECO 531 provides direct readings of dissolved oxygen concentration and oxygen saturation without requiring conversion tables, simplifying water assessment in environmental and aquaculture applications.

Dissolved Oxygen Measurement up to 20 mg/l

Dissolved oxygen concentration indicates the amount of oxygen present in water, providing an important measurement for assessing aquatic environments.

Measuring range: 0.0...20.0 mg/l O₂
Selectable units: mg/l or ppm O₂
Measurement rate: 2 measurements per second

Oxygen Saturation Measurement up to 200 %

In addition to dissolved oxygen concentration, the ECO 531 displays oxygen saturation, allowing water oxygenation levels to be assessed relative to saturation conditions.

Oxygen saturation range: 0...200 % O₂

Galvanic Oxygen Sensor with Active Membrane

The Senseca ECO 531 uses a permanently connected galvanic dissolved oxygen sensor with active membrane and integrated temperature measurement.

Sensor technology: Galvanic
Probe diameter: 12 mm
Probe length: 105 mm
Connection: Fixed cable

Automatic Calibration in Ambient Air

Automatic oxygen calibration can be initiated at the push of a button, using ambient air as a reference, in accordance with the manufacturer's procedure.

Quick and Convenient Adjustment

Simplifies instrument preparation before routine measurements, supporting practical operation in the field.

Salinity Correction from 0 to 70 PSU

Salinity affects the amount of oxygen that can be dissolved in water. The ECO 531 configuration menu allows the salinity value to be entered manually.

Correction range: 0...70 PSU
Applications: Freshwater, brackish water and seawater

Environmental Pressure Setting

The instrument allows the environmental atmospheric pressure to be entered manually, supporting measurement adjustment to local conditions.

Pressure setting range: 500...4000 hPa

Integrated Temperature Measurement

The oxygen probe incorporates an integrated temperature sensor, providing an essential measurement parameter for dissolved oxygen assessment in water.

Temperature measuring range: 0...50 °C
Temperature accuracy: ±0.3 °C
Temperature resolution: 0.1 °C
Selectable units: °C or °F
Operating note: the electrode operating temperature is 0...40 °C, with a recommended operating range of 5...30 °C.

Temperature Input Adjustment

Temperature measuring input corrections can be configured when adjustment is required.

Zero point correction (offset)
Gradient correction

3-Line Backlit LCD for Clear Readings

The illuminated three-line LCD supports clear readings during field measurements.

3-line backlit LCD
Battery status indicator
Bar graph display
Shatterproof screen protection
Overhead display mode at the push of a button

Hold, Min/Max and Automatic Power-Off

Hold: freezes the displayed value.
Min/Max: stores minimum and maximum measured values.
Auto Power-Off: adjustable or deactivated automatic shut-off.
LCD backlight: adjustable switch-off time.

Robust IP65/IP67 Housing for Field Operation

The instrument features a break-proof ABS housing, polyester front panel and IP65/IP67 ingress protection, supporting regular operation in wet environments and field applications.

Dimensions: 108 × 54 × 28 mm
Weight: 240 g
Controls: 4 buttons

More Than 3000 Hours of Battery Life

Extended battery life reduces the need for frequent battery replacement, supporting regular portable operation.

Battery type: 2 × AA alkaline batteries
Typical battery life: >3000 h continuous operation without backlight
Power consumption: 0.8 mA
With backlight: approx. 2.7 mA

Key Advantages of the Senseca ECO 531

• Direct dissolved oxygen readings in mg/l or ppm.

• Oxygen saturation measurement up to 200 %.

• Galvanic sensor with integrated temperature measurement.

• Automatic oxygen calibration in ambient air.

• Manual salinity correction up to 70 PSU.

• Configurable environmental pressure setting.

• Backlit LCD with Hold and Min/Max functions.

• Robust housing with IP65/IP67 protection.

• More than 3000 hours of battery life without backlight.

Applications and Industries

Aquaculture and Fish Farming
Dissolved oxygen checks and assessment of water oxygenation conditions in aquaculture facilities.
Freshwater and Seawater Aquariums
Routine dissolved oxygen measurements in controlled aquatic environments.
Lakes, Ponds and Reservoirs
Assessment of oxygenation conditions in natural and artificial bodies of water.
Rivers and Surface Water
Dissolved oxygen checks during environmental monitoring campaigns.
Wells and Groundwater
Dissolved oxygen measurement in water samples.
Water Treatment
Spot checks of dissolved oxygen concentration in applications compatible with the instrument's measuring ranges.
Research, Education and Laboratories
Portable measurement of dissolved oxygen, oxygen saturation and temperature in water samples.

Technical Specifications

Identification
ManufacturerSenseca
ModelECO 531
Measurement
Analogue inputs1
Dissolved oxygen concentration0.0...20.0 mg/l or ppm O₂
Oxygen saturation0...200 % O₂ saturation
Measurement rate2/s
Temperature measuring range0...50 °C
Temperature accuracy±0.3 °C
Temperature resolution0.1 °C
Temperature units°C / °F
Sensor and Probe
Sensor technologyGalvanic, active membrane
Temperature sensorIntegrated
Probe diameter12 mm
Probe length105 mm
CableFixed cable
Configuration and Calibration
Oxygen calibrationAutomatic calibration in ambient air at the push of a button
Salinity correction0...70 PSU, manual entry
Environmental pressure500...4000 hPa, manual entry
Temperature adjustmentZero point and gradient correction
Ambient Conditions
Instrument operating temperature-20...+50 °C
Electrode operating temperature0...40 °C; recommended 5...30 °C
Operating relative humidity0...95 %RH, short-term condensation possible
Storage temperature0...40 °C
Housing protectionIP65 / IP67
Enclosure
Dimensions108 × 54 × 28 mm
MaterialsBreak-proof ABS housing; polyester front panel
Weight240 g
Power Supply
Battery type2 × AA alkaline
Typical battery life>3000 h continuous operation without backlight
Power consumption0.8 mA; approx. 2.7 mA with backlight
User Interface and Functions
Display3-line backlit LCD with bar graph and battery status indicator
FunctionsHold, Min/Max and overhead display
Automatic power-offAdjustable or deactivated
Controls4 buttons
Compliance
Declaration of conformityCE
Regulatory complianceRoHS, REACH

Frequently Asked Questions – Senseca ECO 531

What does the Senseca ECO 531 measure?
It measures dissolved oxygen concentration in mg/l or ppm, oxygen saturation in percent and water temperature.
What is the dissolved oxygen measuring range?
0.0 to 20.0 mg/l or ppm O₂, with oxygen saturation measurement from 0 to 200 %.
Can the ECO 531 be used in seawater?
Yes. The configuration menu allows manual salinity correction from 0 to 70 PSU for different water salinity conditions.
How is the oxygen sensor calibrated?
Automatic calibration is initiated at the push of a button, using ambient air as a reference, according to the manufacturer's instructions.
Does the ECO 531 measure salinity directly?
No. The salinity value must be known and entered manually in the configuration menu.
What is the electrode operating temperature?
The electrode operating range is 0 to 40 °C, with a recommended range of 5 to 30 °C.
Is the ECO 531 suitable for wet environments?
Yes. The instrument housing provides IP65/IP67 ingress protection for the field operating conditions specified by the manufacturer.
How long do the batteries last?
More than 3000 hours of continuous operation without backlight, using two AA alkaline batteries.
Senseca ECO 531 – Professional Dissolved Oxygen Water Analysis

Improve water quality assessment with a portable solution for dissolved oxygen, oxygen saturation and temperature measurement, particularly suited to aquaculture, fish farming, aquariums and environmental monitoring.

Contact EMI – Electronic Measuring Instruments for commercial information and technical assistance in selecting water quality measurement and monitoring instruments.

Request a Quote

Contact Us

Reviews

Write a review

Waterproof Dissolved Oxygen Meter for Water Analysis - Senseca ECO 531

Waterproof Dissolved Oxygen Meter for Water Analysis - Senseca ECO 531

Dissolved oxygen measurement is an important parameter in water quality assessment, aquatic ecosystem monitoring, aquaculture and fish farming.

9 other products in the same category: