KERN • ORM-CA • Digital Refractometer • Glycol • Brix • ATC
KERN ORM 2CA
Digital Refractometer for Ethylene Glycol, Propylene Glycol and Brix
Product family: KERN ORM-CA
Portable digital refractometer for fast measurement of ethylene glycol, propylene glycol and Brix, particularly suitable for antifreeze, heat-transfer fluids, automotive systems, solar thermal systems and HVAC applications.
Ethylene Glycol – 0–100% and -50 to 0 °C
Propylene Glycol – 0–100% and -60 to 0 °C
0–90% Brix – additional concentration scale
ATC – automatic temperature compensation
IP65 – protection against dust and water jets
Easy Calibration – using commercially available distilled water
The instrument is particularly suitable for checking antifreeze and heat-transfer fluids used in thermal systems, displaying the result directly as a percentage or in °C, depending on the selected scale.
An additional 0 to 90% Brix scale increases the versatility of the instrument, while the digital display and automatic temperature compensation support fast everyday use in workshops, industry, maintenance, solar installations and HVAC systems.
Professional Glycol and Antifreeze Control
The ORM 2CA allows rapid evaluation of the concentration of ethylene glycol and propylene glycol and direct determination of the corresponding freezing point, providing a practical solution for maintenance and thermal system control.
Why Choose the KERN ORM 2CA?
Multiple Scales: ethylene glycol, propylene glycol and Brix in one instrument.
Direct °C Readout: freezing point determination for glycol solutions.
ATC: automatic temperature compensation simplifies measurements.
Digital Display: direct readout and easy interpretation of results.
IP65: protection against dust and water jets.
Quick Calibration: calibration using commercially available distilled water.
Portable Design: compact 121 × 58 × 25 mm housing for everyday field or workshop use.
Ethylene Glycol Measurement
Ethylene glycol is widely used in antifreeze solutions and heat-transfer fluids. The KERN ORM 2CA can display both concentration and the corresponding freezing point.
Concentration: 0 to 100% (v/v)
Resolution: 0.1% (v/v)
Accuracy: ±0.5%
Freezing point: -50 to 0 °C
Temperature resolution: 0.1 °C
Propylene Glycol Measurement
The ORM 2CA also provides dedicated scales for propylene glycol, allowing users to check both concentration and freezing point of the solution.
Concentration: 0 to 100% (v/v)
Resolution: 0.1% (v/v)
Accuracy: ±0.5%
Freezing point: -60 to 0 °C
Temperature resolution: 0.1 °C
0 to 90% Brix Scale
For additional versatility, the ORM 2CA display can also be switched to a Brix scale.
Brix range: 0 to 90%
Resolution: 0.1%
Accuracy: ±0.2%
Automatic Temperature Compensation – ATC
Temperature can significantly influence refractometric measurements. The ORM 2CA incorporates Automatic Temperature Compensation – ATC, reducing the need for manual conversion of measurement results.
This function supports quick and efficient measurements during maintenance, inspection and process control work.
Digital Measurement by Total Reflection
The KERN ORM 2CA uses the total reflection measurement principle to determine the refractometric properties of the sample and automatically convert the result into the selected scale.
Simple Calibration with Distilled Water
The refractometer can be calibrated quickly using commercially available distilled water.
Suitable calibration liquid: 0% – distilled water.
IP65 Protection for Professional Use
The refractometer features an IP65 protection rating, providing protection against dust and water jets.
This construction supports everyday use in workshops, technical installations and industrial environments and makes cleaning easier after use.
Main Applications
Automotive Industry
Checking glycol solutions and antifreeze in workshops, maintenance operations and vehicle manufacturing.
Automotive Workshops
Rapid verification of fluid concentration and freezing protection.
Solar Thermal Systems
Monitoring antifreeze concentration in heat-transfer circuits.
HVAC Systems
Checking glycol solutions in hydraulic circuits, cooling and heating systems.
Chemical Industry
Concentration control in processes using ethylene glycol or propylene glycol solutions.
Industrial Maintenance
Fluid verification in cooling, heating and heat-transfer systems.
Fast and Simple Measurement
• Apply a small amount of sample to the prism.
• Close the prism cover.
• Select the required measurement scale.
• Start the digital measurement.
• Read the result directly on the display.
Technical Specifications
| Identification |
| Manufacturer | KERN & SOHN |
| Model | ORM 2CA |
| Product family | ORM-CA |
| GTIN / EAN | 4045761352759 |
| Measurement System |
| Refractometer type | Digital handheld refractometer |
| Measuring method | Total reflection |
| Display type | Digital |
| Measurement temperature | 0 to 40 °C |
| Temperature compensation | ATC – Automatic Temperature Compensation |
| Ethylene Glycol – EG |
| Concentration range | 0 to 100% (v/v) |
| Resolution | 0.1% (v/v) |
| Accuracy | ±0.5% |
| Freezing point range | -50 to 0 °C |
| Resolution | 0.1 °C |
| Accuracy | ±0.5 °C |
| Propylene Glycol – PG |
| Concentration range | 0 to 100% (v/v) |
| Resolution | 0.1% (v/v) |
| Accuracy | ±0.5% |
| Freezing point range | -60 to 0 °C |
| Resolution | 0.1 °C |
| Accuracy | ±0.5 °C |
| Brix Scale |
| Brix range | 0 to 90% |
| Brix resolution | 0.1% |
| Brix accuracy | ±0.2% |
| Construction & Protection |
| Protection rating | IP65 |
| Dimensions (W × D × H) | 121 × 58 × 25 mm |
| Prism cover | Yes |
| Functions |
| Measurement averaging | Yes |
| Number of measurements for averaging | 15 |
| Auto-Off | 60 seconds |
| Power Supply |
| Power supply | 1 × AAA battery |
Scope of Delivery
• 1 × KERN ORM 2CA digital refractometer.
• Prism cover.
• Pipette.
• Storage box.
• 1 × AAA battery.
• User instructions.
KERN ORM 2CA FAQ
What is the KERN ORM 2CA used for? It is a digital refractometer particularly suitable for measuring ethylene glycol and propylene glycol solutions, including concentration and freezing point.
Does it measure both ethylene glycol and propylene glycol? Yes. The ORM 2CA includes dedicated scales for both glycol types in percentage and in °C.
What is the ethylene glycol range? Concentration can be measured from 0 to 100%, while the freezing point scale covers -50 to 0 °C.
What is the propylene glycol range? Concentration can be measured from 0 to 100%, while the freezing point scale covers -60 to 0 °C.
Does the ORM 2CA measure Brix? Yes. The instrument includes a Brix scale from 0 to 90% with 0.1% resolution.
What does ATC mean? ATC means Automatic Temperature Compensation, reducing the need for manual temperature correction during measurements.
How is the refractometer calibrated? Calibration can be carried out using distilled water, making the process quick and straightforward.
Is the instrument water resistant? The ORM 2CA has an IP65 protection rating, providing protection against dust and water jets.
Is it suitable for solar and HVAC systems? Yes. Its ability to measure glycol concentration and freezing point makes the ORM 2CA particularly suitable for antifreeze control in thermal circuits, solar installations and HVAC systems.
KERN ORM 2CA – Digital Glycol and Antifreeze Control
Need to check the concentration or freezing point of ethylene glycol or propylene glycol in an automotive system, solar circuit, HVAC installation or industrial process? Contact EMI for more information about the KERN ORM 2CA.
Request a Quote
Request Information by Email