The PCE-ATP 1 from PCE Instruments is a portable ATP luminometer designed for rapid surface hygiene verification and assessment of cleaning effectiveness, delivering results in just 10 seconds.
This product is no longer in stock
Availability date:
Suitable for hygiene monitoring programmes, HACCP, food processing, healthcare, pharmaceutical facilities, laboratories, hospitality and catering. Measuring range 0 to 999999 RLU, memory for 10,000 readings, automatic calibration, 3.5" LCD, USB, Bluetooth and analysis software.
Surface hygiene monitoring is an important element of food safety management, cross-contamination prevention and verification of cleaning procedures.
The PCE-ATP 1 from PCE Instruments is a portable ATP luminometer designed for rapid assessment of residual organic material on surfaces using adenosine triphosphate bioluminescence technology.
Used with compatible PCE-ATP Swap test swabs, the instrument provides a quantitative indication of biological and food residues, supporting routine cleaning and hygiene verification programmes.
Results are displayed directly on the large graphical LCD in just 10 seconds and can be stored in the internal memory with date and time information for subsequent analysis and documentation.
Visually clean surfaces may still contain biological or food residues. The PCE-ATP 1 complements visual inspection with quantitative RLU readings, helping quality managers identify areas requiring additional cleaning or corrective action.
ATP (adenosine triphosphate) is a molecule present in living cells and may also be found in food residues and other materials of biological origin.
When the collected sample reacts with the test reagents, a light signal is generated. The luminometer quantifies this signal using a photodiode-based detection system.
According to the manufacturer's description, the system supports quantitative determination of ATP and AMP (adenosine monophosphate), with results expressed in relative light units.
Relative light units express the intensity of the bioluminescence signal. Readings can be compared when measurements are performed under equivalent sampling and testing conditions.
The measurement procedure uses compatible ATP test swabs and reagent tubes for surface sampling and bioluminescence analysis.
Collect a sample from the surface using the test swab, following the sampling area and procedure defined in the hygiene monitoring plan.
Insert and press the swab into the reagent tube according to the manufacturer's instructions.
Gently shake the test tube to allow the collected sample to interact with the reagents in the reaction chamber.
Place the test tube inside the PCE-ATP 1 measuring chamber and initiate the measurement.
After 10 seconds, review the RLU reading, record the result and compare it with the acceptance limits established for the sampling location.
The PCE-ATP 1 supports the implementation and verification of hygiene prerequisite programmes associated with HACCP — Hazard Analysis and Critical Control Points.
• Verification of cleaning procedure effectiveness.
• Surface hygiene checks before production starts.
• Comparison of readings before and after cleaning.
• Identification of areas requiring corrective action.
• Monitoring of cleaning team performance.
• Documentation of results for internal and external audits.
• Support for continuous improvement of food safety programmes.
RLU readings should be interpreted using acceptance limits established and validated by the organisation, taking into account the surface type, sampling area, consumables and application-specific risk.
Result within the established acceptance limit.
Result within a warning range that may require further assessment.
Result above the established acceptance limit, requiring corrective action according to the hygiene plan.
Illustrative classification for a hygiene monitoring programme. Universal RLU acceptance limits cannot be applied to all surfaces and measurement systems.
The internal memory allows hygiene test results to be organised and documented, supporting routine quality checks and analysis of hygiene performance over time.
Measurement results can be transferred for subsequent processing and evaluation using the analysis software supplied with the instrument.
The PCE-ATP 1 features automatic calibration at every start-up and an automatic self-check before each use, simplifying instrument preparation for routine hygiene tests.
The portable design, large graphical display and rechargeable battery make the PCE-ATP 1 suitable for routine hygiene inspections across multiple locations within a facility.
• Quantitative results in just 10 seconds.
• Support for hygiene monitoring and HACCP programmes.
• Rapid identification of areas requiring additional cleaning.
• Faster operational hygiene decisions.
• Memory for 10,000 readings with date and time.
• Organisation by users, plans and test programmes.
• Automatic calibration and self-diagnostics.
• USB and Bluetooth connectivity.
• Analysis software included.
• Portable construction with rechargeable battery.
| Product Identification | |
| Manufacturer | PCE Instruments |
| Model / Reference | PCE-ATP 1 |
| GTIN / EAN | 4250348715913 |
| ATP Measurement | |
| Measuring range | 0...999999 RLU |
| Resolution | 1 RLU |
| Accuracy (original specification label) | 1 × 10-16 mol ATP |
| Detection method | Analogue integration using photodiodes |
| Measurement time | 10 seconds |
| Measurement unit | RLU – Relative Light Units |
| Background noise | ±5 RLU |
| Reproducibility | 8...20 % |
| Calibration | Automatic at every start-up |
| Self-diagnostics | Automatic self-check before each use |
| Memory and Communication | |
| Users | 256 |
| Plans | 256 |
| Test programmes | 2000 |
| Measurement memory | 10,000 records with date and time |
| Interfaces | USB, Bluetooth |
| Software | Included |
| User Interface | |
| Display | 3.5" graphical LCD |
| Menu language | English |
| Power Supply and Battery Life | |
| Rechargeable battery | Li-Ion, 3.7 V / 2300 mAh |
| Continuous operation | 10 h |
| Standby | 600 h |
| Environmental and Mechanical Specifications | |
| Operating temperature | +5...+40 °C |
| Operating humidity | 20...80 %RH |
| Storage temperature | -10...+40 °C |
| Storage humidity | Max. 60 %RH |
| Ingress protection | IP21 |
| Dimensions (L × W × H) | 189 × 70 × 35 mm |
| Weight | Approx. 280 g |
| Standards Referenced in the Documentation | |
| Electrical safety | IEC 61010-1:2010 IEC 61010-2-081:2015 IEC 61010-2-101:2015 |
| Electromagnetic compatibility | IEC 61326-1:2013 IEC 61326-2-6:2013 |
Standards reproduced from the supplied product documentation. Applicable regulatory conformity should be confirmed using the manufacturer's current declaration of conformity.
Compatible ATP test swabs and reagent tubes are required to perform surface hygiene measurements with the PCE-ATP 1.
Important: PCE-ATP Swap consumables are not listed in the stated standard delivery contents. Please confirm the required quantity and availability when ordering.
ATP testing provides a rapid, indirect assessment of surface hygiene and residual organic material.
It does not identify specific microorganisms or pathogens, directly determine colony-forming units (CFU), demonstrate the absence of viable microorganisms or certify surface sterility. ATP testing does not replace microbiological analyses required by applicable procedures or regulatory requirements.
Strengthen cleaning procedures, improve hygiene documentation and obtain quantitative results in just 10 seconds with the PCE-ATP 1 portable ATP luminometer.
EMI – Electronic Measuring Instruments provides professional measurement, quality control and food safety solutions, with technical and commercial assistance in selecting instruments and consumables for your application.