TDSPT101
New product
Product Code: TDSPT101
Compact, wireless sensor delivering accurate temperature and relative humidity readings indoors. Perfect for offices, living areas, and facilities where heavy water/dust protection isn’t required. Works with the Aranet Base Station and Aranet Cloud.
This product is no longer in stock
Availability date:
| Temperature | |
|---|---|
| Range | -40–60 °C (-40–140 °F) |
| Resolution | 0.1 °C (0.1 °F) |
| Accuracy | ±0.3 °C (±0.5 °F) |
| Long-term drift | 0.03 °C/yr (0.05 °F/yr) |
| Time constant (τ) | 13 min |
| Relative Humidity | |
|---|---|
| Range | 0–100 %RH |
| Resolution | 1 %RH |
| Accuracy | ±2 %RH |
| Long-term drift | 0.5 %RH/yr |
| Time constant (τ) | 1 min |
• RH accuracy valid for 0–80 %RH at 23 °C (73 °F). Drift quoted for lab conditions (23 °C, 30–70 %RH); may be higher otherwise.
• Prolonged exposure >80 %RH (condensing) can temporarily increase readings; dry the sensor in low RH to normalize.
| General Specifications | |
|---|---|
| Ingress protection | IP42 |
| Operating temperature | -40–60 °C (-40–140 °F) |
| Dimensions | 92×24×24 mm (3.6×0.9×0.9 in) |
| Weight (incl. battery) | 45 g (1.6 oz) |
| Enclosure material | Polycarbonate |
| Power supply | 1× AA battery |
| Package includes | 1× AA alkaline, double-sided mounting tape |
| Battery Life (interval → runtime) | |
|---|---|
| 1 min | Alkaline: 1.8 years • Lithium: 2.4 years |
| 2 min | Alkaline: 3.2 years • Lithium: 4.6 years |
| 5 min | Alkaline: 6.8 years • Lithium: 10 years |
| 10 min | Alkaline: 10 years • Lithium: 16 years |
• Figures are mathematically extrapolated (no guarantee). Tests at 20 °C using Fujitsu Premium LR6G07 (alkaline) and Energizer Ultimate Lithium L91 (lithium).
• Operating range depends on battery chemistry: alkaline -20–50 °C • lithium -40–60 °C.
| Radio Parameters | |
|---|---|
| Line-of-sight range | Up to 3 km (1.9 mi) |
| Transmitter power | 14 dBm (25 mW) |
| Data transmission interval | 1, 2, 5, or 10 min |
| Data protection | XXTEA encryption |
Performance notes: accuracy valid at purchase in equilibrium. Consider long-term drift. Time constant (τ) is the time to reach 63 % of a new steady state after a step change.

262,50€

43,20€

160,00€

80,00€

742,50€

53,76€

458,00€

226,80€

51,20€

69,00€

112,50€

490,00€