SENSECA • EPS1 • PRESSURE • 4–20 mA • PROCESS • AUTOMATION
Senseca EPS1
Pressure Transmitter with Ceramic Membrane for Liquids and Gases
Industrial pressure transmitter for measuring static and dynamic pressure in liquids and gases, featuring an Al₂O₃ ceramic measuring cell, proportional 4–20 mA two-wire output and a robust all-metal design.
0...1 to 0...100 bar – standard relative pressure ranges
Up to 400 bar – 0...200 and 0...400 bar versions available on request
4–20 mA / 2-wire – easy integration into industrial control systems
Al₂O₃ Ceramic Cell – thick-film measuring technology
6.5 mm Media Bore – helps protect the pressure cell from mechanical damage
Up to 120 °C – with optional gooseneck version
Its robust all-metal construction, combined with an Al₂O₃ ceramic measuring cell, supports universal use in process and industrial automation applications without unnecessarily complicating installation.
The measured pressure is converted into a proportional 4–20 mA two-wire signal, providing a familiar interface for industrial monitoring, control and automation systems.
Pressure Transmitter for Process and Automation
The EPS1 combines a robust ceramic measuring cell, all-metal construction, industrial process connections and a standard 4–20 mA output, providing a practical solution for integration into industrial pressure measurement and control systems.
Protected Pressure Sensor Cell
The pressure cell is connected to the medium through a 6.5 mm bore.
This design helps shield the ceramic pressure cell from mechanical damage during operation, supporting reliable use in industrial applications.
Al₂O₃ Ceramic Measuring Cell
The pressure sensor uses a measuring bridge manufactured using thick-film technology on an aluminium oxide Al₂O₃ ceramic substrate.
This measuring cell converts the applied pressure into an electrical signal which is then provided as a proportional 4–20 mA output.
4–20 mA Two-Wire Industrial Output
The EPS1 converts measured pressure into a proportional 4–20 mA two-wire signal.
This industry-standard output facilitates integration into process and automation environments, allowing pressure measurement to be incorporated into industrial monitoring and control systems.
Relative Pressure Ranges
The EPS1 family covers several relative pressure ranges, allowing the transmitter to be adapted to different process requirements.
Standard ranges: from 0...1 bar up to 0...100 bar.
Available on request: 0...200 bar and 0...400 bar.
Pressure Measurement in Liquids and Gases
The Senseca EPS1 is designed for measuring static and dynamic pressure in liquids and gases, providing a versatile solution for compatible industrial pipework and process systems.
G 1/4 A and G 1/2 A Process Connections
To simplify installation, the pressure transmitter is available with two common industrial process connections.
G 1/4 A: male thread for process installation.
G 1/2 A: male thread for process installation.
The transmitter can be installed in a threaded socket or T-piece, depending on the configuration of the pipework.
Electrical Connection Options
The EPS1 is available with different electrical connection options, allowing the installation to be adapted to the existing infrastructure.
M12x1: 4-pin circular connector.
DIN 43650-A / ISO 4400: industrial plug version.
Clean Cable Alignment after Installation
The continuously rotatable cable outlet allows the cable orientation to be adjusted after the transmitter has been installed, supporting neat and convenient positioning at the installation point.
Option for Medium Temperatures up to 120 °C
For applications involving higher medium temperatures, an optional version with a bendable gooseneck is available.
Medium temperature: up to 120 °C with the gooseneck option.
Key Benefits of the Senseca EPS1
Universal Application: pressure measurement in liquids and gases.
Robust All-Metal Design: developed for industrial applications.
Ceramic Measuring Cell: Al₂O₃ element using thick-film technology.
Protected Sensor Cell: medium connection through a 6.5 mm bore.
Industrial Standard Output: 4–20 mA two-wire signal.
Flexible Installation: G 1/4 A or G 1/2 A with different electrical connection options.
Higher Temperatures: optional version for media temperatures up to 120 °C.
Applications
Industrial Pipework
Static and dynamic pressure measurement in process systems.
Liquid Processes
Pressure monitoring in compatible liquid media.
Gas Processes
Pressure measurement in gases compatible with the transmitter construction.
Industrial Automation
Integration of pressure measurement through a 4–20 mA signal.
Process Control
Continuous pressure monitoring for industrial control systems.
Higher-Temperature Media
Applications up to 120 °C with the optional gooseneck version.
Technical Specifications
| Identification |
| Manufacturer | Senseca |
| Model | EPS1 |
| Type | Pressure transmitter |
| Measurement |
| Pressure type | Relative pressure |
| Media | Liquids and gases |
| Measurement type | Static and dynamic pressure |
| Standard ranges | 0...1 to 0...100 bar |
| Ranges on request | 0...200 bar and 0...400 bar |
| Measuring Element |
| Measuring cell | Al₂O₃ ceramic |
| Technology | Measuring bridge using thick-film technology |
| Media access to measuring cell | 6.5 mm bore |
| Output |
| Output signal | 4...20 mA |
| Configuration | 2-wire |
| Process Connections |
| Connection | G 1/4 A or G 1/2 A male thread |
| Electrical Connection |
| Option 1 | M12x1 circular connector, 4-pin |
| Option 2 | DIN 43650-A / ISO 4400 |
| Orientation | Continuously rotatable cable outlet |
| Temperature |
| Higher-temperature option | Bendable gooseneck version |
| Medium temperature with gooseneck | Up to 120 °C |
Senseca EPS1 FAQ
What does the Senseca EPS1 measure?
The EPS1 measures static and dynamic relative pressure in liquids and gases.
What output does the transmitter provide?
The transmitter provides a proportional 4...20 mA signal in a two-wire configuration.
What type of measuring cell does it use?
It uses an Al₂O₃ ceramic measuring cell with a measuring bridge based on thick-film technology.
Which pressure ranges are available?
Standard ranges extend from 0...1 to 0...100 bar. Versions for 0...200 and 0...400 bar are available on request.
Is an M12 connection available?
Yes. Versions are available with a 4-pin M12x1 circular connector or a DIN 43650-A / ISO 4400 plug.
Which process connections are available?
G 1/4 A and G 1/2 A male process threads are available.
Can it measure both liquids and gases?
Yes. The EPS1 is designed for pressure measurement in liquids and gases.
Is a version available for higher medium temperatures?
Yes. The optional gooseneck version allows operation with medium temperatures up to 120 °C.
Senseca EPS1 – Pressure Measurement for Process and Automation
Need to measure pressure in liquids or gases and integrate the value into an industrial system using a 4–20 mA signal? Contact EMI to select the most suitable pressure range, process connection and electrical connection for your application.