New Combined Probe for IAQ Delta Ohm P37AB147 View larger

Combined Probe for IAQ Delta Ohm P37AB147

P37AB147

New product

Brand: Delta Ohm

Combined probe for temperature, relative humidity, atmospheric pressure, CO2 (Carbon Dioxide) and CO (Carbon Monoxide), with SICRAM module.

To be used in combination with the HD37AB1347 meter for indoor air quality analysis.

Dimensions of the probe: 275 mm x 45 mm x 40 mm. Length of connection cable 2 meters.

More details

520,00€ tax excl.

Add to wishlist

More info

Key Features:

  • CO2 Carbon Dioxide
    • Sensor: NDIR Dual Wavelength
    • Measurement range: 0 to 5000ppm
    • Sensor working range: -5 to 50°C
    • Accuracy: ±50ppm±3% of measurement
    • Resolution: 1ppm
    • Temperature dependence: 0.1%f.s./°C
    • Response time: (T90) < 120 sec (air speed = 2m/sec)
    • Long-term stability: 5% of measurement/5 years
  • CO Carbon Monoxide
    • Sensor: Electrochemical cell
    • Measurement range: 0 to 500ppm
    • Sensor working range: -5 to 50°C
    • Accuracy: ±3ppm±3% of measurement
    • Resolution: 1ppm
    • Response time (T90): < 50 sec
    • Long-term stability: 5% of measurement/year
    • Service life: > 5 years in normal environment conditions
  • Relative Humidity RH
    • Type of sensor: Capacitive
    • Sensor protection: Stainless steel grid filter (upon request 10μm sintered filter P6 in AISI 316 or 20μm sintered filter P7 in PTFE)
    • Measurement range: 0 to 100 % RH
    • Sensor working range: -20 to +60°C
    • Accuracy: ±1.5%RH (0÷90% RH), ±2%RH (elsewhere) for T=15...35°C, ±(1.5+1.5% of the measure) % RH for T= -20 to +60°C
    • Resolution: 0.1°C
    • Temperature dependence: ±2% on all temperature range
    • Hysteresis and repeatability: 1% RH
    • Response time (T90): < 20 sec (air speed = 2m/sec) without filter
    • Long-term stability: 1%/year
  • Temperature T
    • Type of sensor: NTC 10kΩ
    • Measurement range: -20 to +60°C
    • Accuracy: ±0.2°C ±0.15% of measurement
    • Resolution: 0.1°C
    • Response time (T90) < 30 sec (air speed = 2m/sec)
    • Long-term stability 0.1°C/year
  • Atmospheric Pressure Patm
    • Type of sensor Piezo-resistive
    • Measurement range 750 ... 1100 hPa
    • Accuracy ±1.5 hPa @ 25°C
  • Common characteristics
    • Relative Humidity
      • Sensor Capacitive
      • Sensor operating temperature -20 ... 80°C
      • Measurement range 0÷100%RH
      • Resolution 0.1%RH
      • Temperature drift @20°C 0.02%RH/°C
      • Response time %RH: 10sec (10÷80% RH; air speed=2m/s) at constant temperature
    • Temperature with sensor Pt100
      • Resolution: 0.1°C
      • Temperature drift @20°C: 0.003%/°C

See Air Quality Measurement Instrument IAQ Delta Ohm HD37AB1347l:

Reviews

Write a review

Combined Probe for IAQ Delta Ohm P37AB147

Combined Probe for IAQ Delta Ohm P37AB147

Brand: Delta Ohm

Combined probe for temperature, relative humidity, atmospheric pressure, CO2 (Carbon Dioxide) and CO (Carbon Monoxide), with SICRAM module.

To be used in combination with the HD37AB1347 meter for indoor air quality analysis.

Dimensions of the probe: 275 mm x 45 mm x 40 mm. Length of connection cable 2 meters.