Indoor Air Quality IAQ Monitor Delta Ohm HD37AB1347

HD37AB1347

New product

Brand: Delta Ohm

Datalogger for indoor air quality analysis (IAQ). Measurement of airspeed, temperature, relative humidity, atmospheric pressure, CO² and CO. DeltaLog10 software is included for download.

Possibility of connecting a portable thermal printer with the reference: HD40.1

More details

470,00€ tax excl.

Add to wishlist

More info

The instrument measures the quantities: airspeed, temperature, relative humidity, atmospheric pressure, CO2 (Carbon Dioxide) and CO (Carbon Monoxide) by using P37AB147 probe.

The kit consists of: HD37AB1347 instrument, 4 rechargeable 1.2 V AA NiMH batteries, instruction manual, carrying case and Deltalog9 software downloadable here.

Note: Probes and cables must be ordered separately.

The instrument simultaneously measures the following parameters, using the P37AB147 SICRAM
probe: CO2 Carbon Dioxide, CO Carbon Monoxide, Temperature, Relative Humidity, it
calculates Dew Point, Wet Bulb Temperature, Absolute Humidity, Mixing Ratio, Enthalpy and
Atmospheric Pressure.

You can also connect Temperature and Humidity SICRAM combined probes, Hot-Wire Sensor
Wind Speed SICRAM probes, Vane Wind Speed SICRAM probes, and Temperature SICRAM
probes with Pt100 sensor, to the instrument. The instrument with memory capacity of 67,600 records for each of the two inputs. Logging interval from 15 seconds to 1 hour. The software is both powerful and sophisticated, yet user-friendly, the DeltaLog10 software enables data to be organised and analysed to provide management information.

The instrument, using a proper procedure, calculates the percentage of external air input (%
Outside Air) according to CO2 Carbon Dioxide, temperature, and Ventilation Rate.

Reference Standards:

  • Standard ASHRAE 62.1
  • Legislative Decree 81/2008.

These regulations apply to all confined spaces that could be used by people. Kitchens, baths, changing rooms and swimming pools are included, due to their high humidity. You should take into account, in regard to air quality, possible chemical, physical and biological contaminants, or the input of non sufficiently purified external air (Ventilation Rate).

The instrument has a wide Dot Matrix graphic display with a resolution of 160x160 dots.

The detected and computed quantities in the instrument are:

CO2Carbon Dioxideppm
COCarbon Monoxideppm
HrRelative humidity%
T1Temperature detected by the probe connected to input 1°C, °F
PatmAtmospheric PressurehPa
VaWind Speedm/ s, km/ h, ft/ min, mph, nó
FVaFlow RateL/ s, m3/ h, m3/ min, m3/ h, ft3/ s, ft3/ min
T2Temperature detected by the probe connected to input 2°C, °F
TdDew Point°C, °F
TwWet Bulb Temperature°C, °F
AHAbsolute Humidityg/ m3
rMixing Ratiog/ kg
HEnthalpykJ/ kg

The instrument typical applications, using the above range of probes, are:

  • Measurement of IAQ (Indoor Air Quality) and comfort conditions in schools, offices and
  • indoor spaces.
  • Analysis and study of the Sick Building Syndrome, and of the resulting consequences.
  • Checking the HVAC (Heating, Ventilation and Air Conditioning) system efficiency.
  • Examination of IAQ conditions in factories to optimize microclimate and improve
  • productivity.
  • Building Automation checks.

Main Characteristics of the Combined Probe for analysis of indoor air quality (IAQ). Reference: P37AB147

  • CO2 Carbon Dioxide
    • Sensor: NDIR Dual Wavelength
    • Measurement range: 0 to 5000 ppm
    • Sensor working range: -5 to 50°C
    • Accuracy: ±50 ppm ±3% of measurement
    • Resolution: 1 ppm
    • Temperature dependence: 0.1% f.s./ °C
    • Response time (T90): < 120 sec (air speed = 2m/sec)
    • Long-term stability: 5% of measurement/5 years
  • CO Carbon Monoxide
    • Sensor: Electrochemical cell
    • Measurement range: 0 to 500 ppm
    • Sensor working range: -5 to 50°C
    • Accuracy: ±3 ppm ±3% of measurement
    • Resolution: 1ppm
    • Response time (T90): <50 sec
    • Long-term stability: 5% of measurement/year
    • Service life: > 5 years in normal environment conditions
  • Relative Humidity RH
    • Type of sensor: Capacitive
    • Sensor protection: Stainless steel grid filter (upon request 10μm sintered filter P6 in AISI 316 or 20μm sintered filter P7 in PTFE)
    • Measurement range: 0 to 100 % RH
    • Sensor working range: -20 to +60°C
    • Accuracy ±1.5%RH (0 to 90% RH), ±2% RH (elsewhere) for T=15 to 35°C,±(1.5 + 1.5% of the measure) % RH for T= -20 to +60°C
    • Resolution: 0.1°C
    • Temperature dependence: ±2% on all temperature range
    • Hysteresis and repeatability: 1% RH
    • Response time: (T90) < 20 sec (air speed = 2m/ sec) without filter
    • Long-term stability: 1%/year
  • Temperature T
    • Type of sensor: NTC 10kΩ
    • Measurement range: -20 to +60°C
    • Accuracy: ±0.2°C ±0.15% of measurement
    • Resolution: 0.1°C
    • Response time (T90): < 30 sec (air speed = 2m/sec)
    • Long-term stability: 0.1°C/year
  • Atmospheric Pressure (Patm)
    • Type of sensor: Piezo-resistive
    • Measurement range: 750 to 1100 hPa
    • Accuracy: ±1.5 hPa @ 25°C
  • Common characteristics
    • Relative Humidity
      • Sensor: Capacitive
      • Sensor operating temperature: -20 to 80 ° C
      • Measurement range: 0 to 100% hr
      • Resolution: 0,1% hr
      • Temperature drift @20°C: 0,02% hr/ °C
      • Response time %RH: 10sec (10÷80% RH; air speed=2m/s) at constant temperature
    • Temperature with sensor Pt100
      • Resolution 0,1 ° C
      • Temperature drift @20°C: 0.003%/ °C

Hot-Wire Air Speed measurement probes with SICRAM module: AP471 S1 - AP471 S2 - AP471 S3 - AP471 S4

AP471 S1, AP471 S3AP471 S2AP471 S4
Type of measurements:Air speed, calculated flow rate, air temperatureAir speed, calculated flow rate, air temperatureAir speed, calculated flow rate, air temperature
Type of sensor
Velocity:NTC ThermistorOmni direcional NTC ThermistorOmni direcional NTC Thermistor
Temperature:NTC ThermistorNTC ThermistorNTC Thermistor
Measurement range
Velocity:0.1 to 40m/s0.1 to 5m/s0.1 to 5m/s
Temperature:-25 to +80°C-25 to +80°C0 to 80°C
Measurement resolution
Velocity:0.01 m/s
0.1 km/h
1 ft/min
0.1 mph
0.1 knot
0.01 m/s
0.1 km/h
1 ft/min
0.1 mph
0.1 knot
0.01 m/s
0.1 km/h
1 ft/min
0.1 mph
0.1 knot
Temperature:0.1°C0.1°C0.1°C
Measurement accuracy
Velocity:±0.2 m/s (0 to 0.99 m/s)
±0.4 m/s (1.00 to 9.99 m/s)
±0.8 m/s (10.00 to 40.0 m/s)
±0.2m/s (0 to 0.99 m/s)
±0.3m/s (1.00 até 5.00 m/s)
±0.2m/s (0 to 0.99 m/s)
±0.3m/s (1.00 até 5.00 m/s)
Temperature:±0.8°C (-10 to +80°C)±0.8°C (-10 to +80°C)±0.8°C (-10 to +80°C)
Minimum speed:0.1 m/s0.1 m/s0.1 m/s
Air temperature compensation:0 to 80°C0 to 80°C0 to 80°C
Sensor working conditions:Clean air, RH<80 %Clean air, RH<80 %Clean air, RH<80 %
Battery life:Approx. 20 hours @ 20 m/s
with alkaline batteries
Approx. 30 hours @ 5 m/s with alkaline batteriesApprox. 30 hours @ 5 m/s with alkaline batteries
Unit of measurement
Velocity:m/s, km/h, ft/min, mph, knotm/s, km/h, ft/min, mph, knotm/s, km/h, ft/min, mph, knot
Flow rate:l/s, m3/s, m3/min, m3/h, ft3/s, ft3/minl/s, m3/s, m3/min, m3/h, ft3/s, ft3/minl/s, m3/s, m3/min, m3/h, ft3/s, ft3/min
Pipeline section for flow rate calculation:0.0001 to 1.9999 m20.0001 to 1.9999 m20.0001 to 1.9999 m2
Cable length:±2 meters±2 meters±2 meters

Vane Air Speed measurement probes with SICRAM module: AP472 S1 - AP472 S2

AP472AP472 S2
Type of measurements:Air speed,calculated flow rate,air temperatureAir speed,calculated flow rate,air temperature
Diameter:100 mm60 mm
Type of measurements:
Velocity:VaneVane
Temperature:Termocouple tyoe K
Measurement range
Velocity (m/s):0.6 to 250.5 to 20
Temperature (°C):-25 to+80(*)-25 to +80(*)
Resolution
Velocity:0.01 m/s
0.1 km/h
1 ft/min
0.1 mph
0.1 knot
0.01 m/s
0.1 km/h
1 ft/min
0.1 mph
0.1 knot
Temperature:0,1°C
Accuracy
Velocity:±(0.4 m/s +1.5%f.s.)±(0.4 m/s +1.5%f.s.)
Temperature:±0.8°C
Minimum speed:0.6 m/s0.5 m/s
Unit of measurement
Velocity:m/s, km/h, ft/min, mph, knotm/s, km/h, ft/min, mph, knot
Flow rate:l/s, m3/s, m3/min, m3/h, ft3/s, ft3/minl/s, m3/s, m3/min, m3/h, ft3/s, ft3/min
Pipeline section for flow rate calculation:0.0001 to 1,9999 m20.0001 to 1,9999 m2
Cable lengh:±2 meters±2 meters

(*) The indicated value refers to the vane’s working range.

Temperature probes Pt100 using SICRAM module:

ModelTypeApp. rangeAccuracy
TP472IImmersion-196°C to +500°C±0.1°C (@ 0°C)
±0.2°C (-50°C ≤ t ≤ 250°C)
±0.3°C (t < -50°C; t > 250°C)
TP472I.O
1/3DIN - Thin film
Immersion-50°C to +300°C±0.1°C (@ 0°C)
±0.2°C (-50°C ≤ t ≤ 250°C)
±0.3°C (t < -50°C; t > 250°C)
TP473P.IPenetration-50°C to +400°C±0.1°C (@ 0°C)
±0.2°C (-50°C ≤ t ≤ 250°C)
±0.3°C (t < -50°C; t > 250°C)
TP473P.O
1/3DIN - Thin film
Penetration-50°C to +300°C±0.1°C (@ 0°C)
±0.2°C (-50°C ≤ t ≤ 250°C)
±0.3°C (t < -50°C; t > 250°C)
TP474C.0
1/3DIN - Thin film
Contact-50°C to +300°C±0.1°C (@ 0°C)
±0.2°C (-50 °C ≤ t ≤ 250°C)
±0.3°C (t < -50°C; t > 250°C)
TP475A.O
1/3DIN - Thin film
Air-50°C to +250°C±0.1°C (@ 0°C)
±0.2°C (-50°C ≤ t ≤ 250°C)
TP472I.5Penetration-50°C to +400°C±0.1°C (@ 0°C)
±0.2°C (-50°C ≤ t ≤ 250°C)
±0.3°C (t < -50°C; t > 250°C)
TP472I.10Penetration-50°C to +400°C±0.1°C (@ 0°C)
±0.2°C (-50 °C ≤ t ≤ 250°C)
±0.3°C (t < -50°C; t > 250°C)
TP49A.I
Classe A - Thin film
Immersion-70°C to +250°C±0.1°C (@ 0°C)
±0.2°C (-50 °C ≤ t ≤ 250°C)
±0.3°C (t < -50°C; t > 250°C)
TP49AC.I
Classe A - Thin film
Contact-70°C to +250°C±0.1°C (@ 0°C)
±0.2°C (-50 °C ≤ t ≤ 250°C)
±0.3°C (t < -50 °C; t > 250°C
TP49AP.I
Classe A - Thin film
Penetration-70°C to +250°C±0.1°C (@ 0°C)
±0.2°C (-50°C ≤ t ≤ 250°C)
TP875.IGlobethermometer
Ø150mm
-30°C to +120°C±0.1°C (@ 0°C)
±0.2°C (-50°C ≤ t ≤ 250°C
TP876.IGlobethermometer
Ø50mm
-30°C to +120°C±0.1°C (@ 0°C)
±0.2°C (-50°C ≤ t ≤ 250°C
TP87.0
1/3DIN - Thin film
Immersion-50°C to +200°C±0.1 °C (@ 0°C)
±0.2 °C (-50°C ≤ t ≤ 250°C
- TP878.0
1/3DIN - Thin film
- TP878.1.O
For solar panel+4°C to +85°C±0.1°C (@ 0°C)
±0.2°C (-50 °C ≤ t ≤ 250°C)
TP879.0For compost-20°C to +120°C±0.1 °C (@ 0°C)
±0.2 °C (-50°C ≤ t ≤ 250°C)

Common characteristics, Temperature drift @ 20°C: 0.003%/°C

See Combined Probe for IAQ, Temperature, Relative Humidity, Atmospheric Pressure, CO2 and CO Delta Ohm P37AB147:

Reviews

Write a review

Indoor Air Quality IAQ Monitor Delta Ohm HD37AB1347

Indoor Air Quality IAQ Monitor Delta Ohm HD37AB1347

Brand: Delta Ohm

Datalogger for indoor air quality analysis (IAQ). Measurement of airspeed, temperature, relative humidity, atmospheric pressure, CO² and CO. DeltaLog10 software is included for download.

Possibility of connecting a portable thermal printer with the reference: HD40.1